62131
OPERATOR’S MANUAL
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
RELEASED: 10-13-04
REVISED:
(REV. 05)
5-24-10
SELF EVACUATING OIL DRAIN
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
OPERATING AND SAFETY PRECAUTIONS
1
EXCESSIVE AIR PRESSURE. Can cause explosion resulting in
WARNING
severe injury or death.
3
S Do not exceed the maximum inlet air pressure as stated on the model plate.
5
EXPLOSIONHAZARD.Cancauseseriousinjuryorpropertydam-
WARNING
age.
S Do not use near open flame or heat source.
8
7
S This product is not designed for working in explosive environments, including
those caused by fumes and dust, or near flammable materials.
HAZARDOUS MATERIALS. Can cause personal injury or proper-
WARNING
30
10
ty damage.
S Do not use for volatile fuel and fluids.
S Obtain Material Safety Data Sheets on all materials from the supplier for proper
handling instructions.
HIGH PRESSURE AIR. Bypassing, modifying or removing the
safety / relief valve can cause serious injury or death. Do not bypass, modify or
remove the safety / relief valve. Do not direct air stream at body.
WARNING
31
32
29
Be certain all operators of this equipment have been trained for
CAUTION
safe working practices, understand it’s limitations and wear safety goggles /
equipment when required.
S Do not use for structural support.
18
S Disconnect air supply when not in use.
S Use only genuine IR replacement parts to assure longest service life.
GENERAL DESCRIPTION
Model62131isawasteoilcontainerwhichstoresupto20gallons(75.7liters)inanASME
certified steel tank and rapidly discharges using air pressure. The unit is equipped with a
safety relief valve which prevents over-pressurization and a 4-3/4” x 20-1/2” (12.0 cm x
52.0 cm) drain funnel with a filtering screen and a telescoping tube. The tank has (2) rigid
casters and (2)swivelcastersforeasymaneuvering. Italso includesa sightgauge andan
oil shut-off valve.
19
OPERATION
1. Toraisethefunnel:Grasptheupperportionofthe(5)tube,loosenthe(6)thumbscrew
and raise the funnel and tube to the desired height. Tighten the (6) thumb screw and
release grasp on tube.
2. To lower the funnel: Grasp the upper portion of (5) tube, loosen the (6) thumb screw
and lower the funnel and tube to the desired position. Tighten (6) thumb screw and
release grasp on tube.
20
Figure 1
FLOAT VALVE SERVICE PROCEDURES
1. Depressurize system before and during servicing.
3. The reservoir includes a sight gauge. Do not overfill the reservoir.
4. To evacuate oil: Lower the (1) funnel. Always connect the discharge hose before con-
necting air supply. Connect the discharge hose to the (9) oil shut-off valve on the (18)
tank. Be sure the (9) oil shut-off valve is fully engaged. Open the (9) oil shut-off valve.
Before connecting the air supply, be sure that the inlet air line pressure is regu-
lated at no more than 70 p.s.i. (PMAX). Connect the air supply to the (10) air man-
ifold.Neverleavetheunitunattendedduringevacuation.Closethe(12)airshut-off
valve immediately when the tank is empty. The discharge hose will begin to shake
when the (18) tank is empty. Disconnect the air supply to the (10) air manifold. Close
the(9)oilshut-offvalve.Slowlyopenthe(12)airshut-offvalvetodepressurizethesys-
tem. System must be depressurized before returning to service. Disconnect the dis-
charge hose from the (9) oil shut-off valve on the (18) tank. Periodically remove and
clean the (2) funnel screen as necessary.
2. Wear appropriate safety equipment during servicing.
3. Remove (1) funnel from (5) tube.
4. Remove (6) thumbscrew from (7) collar.
5. Unbolt (30) handle and remove from the (18) tank.
6. Loosen the (7) collar and remove the (5) tube from the (18) tank.
7. To loosen the (7) collar, it may require the use of an industrial heat gun to soften the
pipe thread sealant on the (7) collar thread.
a. WARNING -- Do not use an open flame.
b. WARNING -- Be sure the tank vents are open during service.
c. WARNING -- Keep heat away from product labels.
8. Use a large spanner wrench or 12” pipe wrench to remove the (7) collar.
9. Secure tank when removing the collar.
10. Remove the (27) roll pin and the (25) ball from the (26) seat.
11. Remove the (26) seat by unscrewing the seat from the (5) tube.
12. Removedebrisandparticulatesfromthe(27)rollpin,(25)balland(26)seatusingmild
detergent and water.
a. WARNING -- Do not use solvent, as this may damage the ball.
13. Before reassembly, apply PTFE tape to the (26) seat threads.
14. Assemble in reverse order. Apply Loctite PST or equivalent pipe thread sealant to the
(7) collar threads prior to assembly. Tighten securely.
5. (17) safety relief valve may discharge during evacuation.
DATA
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 lbs (47.6 kgs)
Recommended Air Operating Pressure . . . . . . 20 - 70 p.s.i.g. (1.38 - 4.83 bar)
Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 gallons (75.7 liters)
Height . . . . . . (lowered) . . . . . . . . . . . . . . . . 52 in. (132.08 cm)
(fully extended) . . . . . . . . . . . 73 in. (185.42 cm)
15. Test all joints for air leakage prior to putting drain back into service.
Tank Diameter . . . . . . . . . . . . . . . . . . . . . . . . . 16 in. (40.64 cm)
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
CCN 15231640
© 2010